Vista 1 del producto
Vista 1 del producto
Imagen

Conector N Macho para cable AVA6-50

  • Conector N Macho para cable 1-1/4 in FXL1480/AVA6-50
  • IMD de tercer orden -116 dBm @ 1800 MHz
  • Potencia máxima de pico 10 kW @ 900 MHz
  • Rango de frecuencia operativa 0-4000 MHz
  • Protección IP68 e IP66 para ambientes hostiles

Especificaciones

Electrical Specifications
Connector Impedance 50 ohm
Operating Frequency Band 0 – 3300 MHz
Cable Impedance 50 ohm
3rd Order IMD, typical -116 dBm @ 1800 MHz
3rd Order IMD Test Method Two +43 dBm carriers
RF Operating Voltage, maximum (vrms) 707.00 V
dc Test Voltage 2000 V
Outer Contact Resistance, maximum 0.30 mOhm
Inner Contact Resistance, maximum 2.00 mOhm
Insulation Resistance, minimum 5000 MOhm
Average Power 0.6 kW @ 900 MHz
Peak Power, maximum 10.00 kW
Insertion Loss, typical 0.05 dB
Shielding Effectiveness -130 dB
Mechanical Specifications
Outer Contact Attachment Method Clamp
Inner Contact Attachment Method Captivated
Outer Contact Plating Trimetal
Inner Contact Plating Silver
Attachment Durability 25 cycles
Interface Durability 500 cycles
Interface Durability Method IEC 61169-4:9.5
Connector Retention Tensile Force 1334 N | 300 lbf
Connector Retention Torque 8.13 N-m | 72.00 in lb
Insertion Force 66.72 N | 15.00 lbf
Insertion Force Method IEC 61169-1:15.2.4
Pressurizable No
Coupling Nut Proof Torque 24.86 N-m | 220.00 in lb
Coupling Nut Retention Force 1000.85 N | 225.00 lbf
Dimensions & Weight
Nominal Size 1-1/4 in
Diameter 49.00 mm | 1.93 in
Length 72.00 mm | 2.83 in
Weight 302.00 g | 0.67 lb
Environmental Specifications
Operating Temperature -40 °C to +85 °C (-40 °F to +185 °F)
Storage Temperature -55 °C to +85 °C (-67 °F to +185 °F)
Immersion Depth 1 m
Immersion Test Mating Mated
Immersion Test Method IEC 60529:2001, IP68
Water Jetting Test Mating Mated
Water Jetting Test Method IEC 60529:2001, IP66
Moisture Resistance Test Method MIL-STD-202F, Method 106F
Mechanical Shock Test Method MIL-STD-202F, Method 213B, Test Condition C
Vibration Test Method IEC 60068-2-6
Standard Conditions & Performance
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Coupling Nut Retention Force Method MIL-C-39012C-3.25, 4.6.22
Corrosion Test Method MIL-STD-1344A, Method 1001.1, Test Condition A
Return Loss / VSWR Performance
Frequency Band VSWR Return Loss (dB)
50–1000 MHz 1.03 38.00
1000–1900 MHz 1.03 37.00
1900–2200 MHz 1.04 35.00
2200–2700 MHz 1.05 33.00
2700–3300 MHz 1.07 30.00
Regulatory Compliance & Certifications
RoHS 2011/65/EU Compliant by Exemption
China RoHS SJ/T 11364-2006 Above Maximum Concentration Value (MCV)
ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system